Stack of white papers topped with a State of Maine Professional Engineer stamp on the top document.

Written by Acorn Sales Company, manufacturing stamps and seals since 1964 · Reviewed by Holly R, VP of Sales and Marketing at Acorn Sales, against the State Board of Licensure for Professional Engineers and 32 M.R.S. § 1355 on 21 September 2026 · Updated 21 September 2026

A Maine PE seal is 1-3/4 inches in diameter, the trade size known as Size #1, and that figure comes from the board’s published Approved Seal Format page rather than from the rule. 02-322 C.M.R. ch. 2 § 9(1) says only that the licensee may obtain “a seal of the size and design prescribed by the Board.” A supplier quoting Maine from the regulation alone finds no dimension at all, which is why the two sources have to be cited together.

Maine is also unusually generous about what does not need sealing. 02-322 C.M.R. ch. 2 § 9(6) carves out four categories: documents clearly identified as PRELIMINARY or PROGRESS or the like, individual specification sections folded into an integrated document sealed by another licensed engineer or architect, electronic files such as CAD files delivered to a client provided the licensee affixes a statement naming the licensee, the PE license number and the date of original sealing, and administrative correspondence. Engineers who stamp everything by reflex are producing sealed preliminaries.

There is no certificate of authorization for engineering firms in Maine. 32 M.R.S. § 1253 permits a firm, copartnership, corporation or joint stock association to practice provided the practice is carried on only by engineers licensed in the state. No firm number goes on the document and there is no firm seal.

Maine PE seal requirements at a glance

Requirement Maine rule Source
Seal required Yes 32 M.R.S. § 1355
Required elements The words “State of Maine”, Your name as licensed, Your license number and The words “Licensed Professional Engineer” 32 M.R.S. § 1355
Size and shape 1-3/4 inches in diameter, the trade size known as Size #1. That figure comes from the board’s published Approved Seal Format page, not from the rule text: 02-322 C.M.R. ch. 2 § 9(1) says only that the licensee may obtain “a seal of the size and design prescribed by the Board.” The board page is where the prescription actually lives, so cite both. Board publication “Approved Seal Format”
Device allowed Three formats are authorized by rule: “The seal may be an embossed seal, a rubber stamp or an electronically generated image.” The board repeats this in plainer words: the seal can be a physical or wet seal or an electronically applied seal. 02-322 C.M.R. ch. 2 § 9(1), (4)
Signature and date The rule ties all three together: “The Licensee’s signature and the date must accompany the seal. 02-322 C.M.R. ch. 2 § 9(3), (10), (11)
What must be sealed Required on plans, specifications, reports and calculations prepared by or under the direction of the responsible licensee, on anything formally filed or offered for filing with a public body or agency, and on anything formally submitted to contractors for bids or estimates or released for construction. 02-322 C.M.R. ch. 2 § 9(5), (6)
Electronic seal Maine names no engineering-specific cryptographic standard. 02-322 C.M.R. ch. 2 § 9(1), (3), (4)
Renewal and lapse Licenses expire on the last day of December of each odd-numbered year and a licensee may not practice with an expired license. 32 M.R.S. §§ 1355, 1357, 1361
Firm number on documents Not applicable. 32 M.R.S. § 1253
Licensing board The State Board of Licensure for Professional Engineers 32 M.R.S. ch. 19 (Engineers), read section by section on the Maine Legislature site, with §§ 1253, 1255, 1355, 1357

Rules for other states are on PE stamp requirements by state.

Is a seal required in Maine?

Maine requires a seal Maine splits the duty. The statute creates the device and the general obligation: 32 M.R.S. § 1355 provides that each licensee may obtain “a seal of the design authorized by the board, bearing the licensee’s name and the legend ‘licensed professional engineer’” and that “Plans, specifications, plats and reports issued by a licensee must be stamped with the seal, as prescribed in the rules of the board.” The rule then supplies the trigger list. Under 02-322 C.M.R. ch. 2 § 9(5) a seal must be applied, signed and dated, in hardcopy or electronic versions, on all professional engineering plans, specifications, reports or calculations prepared by or under the direction of the responsible licensed professional engineer, on all such documents formally filed or offered for filing with any public body or agency, and on all such documents formally submitted to contractors for bids or estimates or released for construction.

What must appear on the seal

  • The words “State of Maine”
  • Your name as licensed
  • Your license number
  • The words “Licensed Professional Engineer”

The license number is an example of board guidance filling a statutory gap: 32 M.R.S. § 1355 names only the licensee’s name and the legend, but the board’s published Approved Seal Format requires the license number as well. The board also addresses how the number may be introduced: it “may be preceded by any designation likely to indicate to an observer that it is the license number (e.g. PE00000, License Number 00000, Lic. 00000, No. 00000, #00000, etc.)”, and since license numbers are the only numbers on the seal, no designation is actually required. The board asks for all capitals: “Lettering should be in ALL CAPS, so the seal remains clear even after image transfer.” No engineering discipline belongs on a Maine seal.

Size and shape

1-3/4 inches in diameter, the trade size known as Size #1. That figure comes from the board’s published Approved Seal Format page, not from the rule text: 02-322 C.M.R. ch. 2 § 9(1) says only that the licensee may obtain “a seal of the size and design prescribed by the Board.” The board page is where the prescription actually lives, so cite both.

Embosser, rubber stamp or digital

Three formats are authorized by rule: “The seal may be an embossed seal, a rubber stamp or an electronically generated image.” The board repeats this in plainer words: the seal can be a physical or wet seal or an electronically applied seal. The safe buy is a 1-3/4 inch rubber stamp, which satisfies the board’s own concern about clarity after image transfer better than an embosser. Sealed documents may be transmitted electronically under § 9(4).

Signing and dating

The rule ties all three together: “The Licensee’s signature and the date must accompany the seal. Effective signature may be an electronic signature as defined by 10 M.R.S.A. Section 9402.” The date is the date of sealing, not a license expiration date, and there is no requirement to sign across the seal. Revisions are treated separately: any revision to a sealed and signed document must be described and dated, and if the revision is not done by the original licensee it must also be signed and sealed by the licensee in responsible charge of the revision. A licensee holding a Maine temporary license stamps with the seal of their home jurisdiction and writes the Maine temporary license number beneath it, with signature and date.

One seal on a bound set, or a sheet count next to it

Maine writes down what most states leave to custom. 02-322 C.M.R. ch. 2 § 9(9) provides that where plans, specifications, reports or calculations are bound together, the application of the seal on the first sheet or page is considered sufficient if the intent is to cover the entire document, otherwise the first sheet must also include a statement of the number of sheets covered by each licensee’s seal.

Which documents must be sealed

Required on plans, specifications, reports and calculations prepared by or under the direction of the responsible licensee, on anything formally filed or offered for filing with a public body or agency, and on anything formally submitted to contractors for bids or estimates or released for construction. Maine then gives four express carve-outs in § 9(6), which is unusually generous: documents prepared and clearly identified as “PRELIMINARY,” “PROGRESS,” or the like; individual specification sections that are part of an integrated document assembled and sealed by another licensed engineer or licensed architect; electronic files such as CAD files submitted as a deliverable to a client, provided the licensee affixes a statement such as “This document was originally issued and sealed by (Licensee Name, PE License #), on (Date of original sealing)”; and administrative correspondence.

Electronic and digital seals

Maine names no engineering-specific cryptographic standard. It borrows the general state definition: an effective signature “may be an electronic signature as defined by 10 M.R.S.A. Section 9402”, which is Maine’s Uniform Electronic Transactions Act. The seal itself may be an electronically generated image, and sealed documents may be transmitted electronically. There is no requirement for a digital certificate, a tamper-evident container or an approved vendor.

Renewal, lapse and retirement

Licenses expire on the last day of December of each odd-numbered year and a licensee may not practice with an expired license. A license may be renewed up to 90 days after expiration on payment of a late fee in addition to the renewal fee. 32 M.R.S. § 1355 makes it “unlawful for anyone to stamp or seal any document with the seal after the license of the licensee named thereon has expired or has been revoked, unless the license has been renewed or reissued.” Retirement is handled distinctively: under 32 M.R.S. § 1361 “A retired licensee may retain but not use the seal and may not practice engineering.” Nothing must be surrendered or destroyed. Whether a license number changes on reinstatement is not addressed in 32 M.R.S. § 1357 or in 02-322 C.M.R. ch. 2.

Firm registration

Not applicable. Maine has no certificate of authorization for engineering firms. 32 M.R.S. § 1253 provides only that “A firm, copartnership, corporation or joint stock association may engage in the practice of professional engineering in this State, provided that the practice is carried on only by professional engineers licensed in this State.” There is no firm number to place on the document and no firm seal.

What to check before you order

Order 1-3/4 inches outside diameter, Size #1, carrying STATE OF MAINE, your name, your license number, and LICENSED PROFESSIONAL ENGINEER. Set the lettering in all capitals, which the board asks for so the seal survives image transfer; the number may carry a PE, No., Lic. or # prefix or none at all, and do not add a discipline. Embosser, rubber stamp and electronically generated image are all legal, and the rubber stamp is the one to take. If you seal bound sets, the first-sheet seal covers the set only if that is the intent, and otherwise a sheet count has to appear on the first sheet. You do not need to show proof of licensure to buy one, and nothing is filed with the board.

Browse professional engineer stamps and seals.

More on this topic

Frequently asked questions

What size is a Maine PE seal?

1-3/4 inches in diameter, Size #1, per the board’s Approved Seal Format page. Cite the rule with it, because 02-322 C.M.R. ch. 2 § 9(1) prescribes only a seal of the size and design prescribed by the board and states no number. The board page is where the prescription actually lives.

Is a seal required in Maine?

Yes, and the duty is split between statute and rule. 32 M.R.S. § 1355 creates the device, providing for “a seal of the design authorized by the board, bearing the licensee’s name and the legend ‘licensed professional engineer’” and requiring that “Plans, specifications, plats and reports issued by a licensee must be stamped with the seal, as prescribed in the rules of the board.” 02-322 C.M.R. ch. 2 § 9(5) supplies the trigger list.

What has to appear on a Maine PE seal?

State of Maine, your name as licensed, your license number, and the words Licensed Professional Engineer. The license number is a board addition rather than a statutory one: 32 M.R.S. § 1355 names only the name and the legend, while the board’s Approved Seal Format requires the number as well. No engineering discipline belongs on a Maine seal.

How should the license number be shown on a Maine seal?

However you like, or not labeled at all. The board provides that the number “may be preceded by any designation likely to indicate to an observer that it is the license number (e.g. PE00000, License Number 00000, Lic. 00000, No. 00000, #00000, etc.)”, and since license numbers are the only numbers on the face, no designation is actually required. The board does ask for capitals throughout: “Lettering should be in ALL CAPS, so the seal remains clear even after image transfer.”

Embosser, rubber stamp or electronic image in Maine?

All three are authorized by rule: “The seal may be an embossed seal, a rubber stamp or an electronically generated image.” A 1-3/4 inch rubber stamp is the practical choice, since it answers the board’s own concern about legibility after image transfer better than an embosser does. Sealed documents may be transmitted electronically under § 9(4).

Where do the signature and date go in Maine?

With the seal, and there is no requirement to sign across it. § 9(3) provides that “The Licensee’s signature and the date must accompany the seal. Effective signature may be an electronic signature as defined by 10 M.R.S.A. Section 9402.” The date is the date of sealing, not a license expiration date. Revisions are handled separately: any revision to a sealed and signed document must be described and dated, and if the revision is not done by the original licensee it must also be signed and sealed by the licensee in responsible charge of the revision.

Which documents have to be sealed in Maine?

Plans, specifications, reports and calculations prepared by or under the direction of the responsible licensee, anything formally filed or offered for filing with a public body or agency, and anything formally submitted to contractors for bids or estimates or released for construction, per § 9(5). Against that, § 9(6) lists four express carve-outs: documents clearly marked PRELIMINARY or PROGRESS, individual specification sections within someone else’s sealed integrated document, CAD and similar electronic files delivered to a client where the licensee affixes a statement such as “This document was originally issued and sealed by (Licensee Name, PE License #), on (Date of original sealing),” and administrative correspondence.

Do I have to seal every sheet of a bound set in Maine?

No, if the intent is to cover the whole document. § 9(9) provides that where plans, specifications, reports or calculations are bound together, applying the seal on the first sheet or page is sufficient if the intent is to cover the entire document, and otherwise the first sheet must also include a statement of the number of sheets covered by each licensee’s seal. That single sentence changes the order: a Maine engineer sealing a cover page may need only a hand stamp, but the impression has to be clean, because it is carrying the set.

What does Maine require for an electronic or digital signature?

No engineering-specific standard. Maine borrows the general state definition: an effective signature “may be an electronic signature as defined by 10 M.R.S.A. Section 9402,” which is Maine’s Uniform Electronic Transactions Act. The seal itself may be an electronically generated image, and sealed documents may be transmitted electronically. There is no digital certificate requirement, no tamper-evident container requirement and no approved vendor list.

What happens to my Maine seal at renewal or retirement?

Licenses expire on the last day of December of each odd-numbered year, and a licensee may not practice on an expired license. Renewal is available up to 90 days after expiration on payment of a late fee in addition to the renewal fee. 32 M.R.S. § 1355 makes it “unlawful for anyone to stamp or seal any document with the seal after the license of the licensee named thereon has expired or has been revoked, unless the license has been renewed or reissued.” Retirement is handled distinctively: under 32 M.R.S. § 1361 “A retired licensee may retain but not use the seal and may not practice engineering.” Nothing has to be surrendered or destroyed. Whether a license number changes on reinstatement is not addressed in 32 M.R.S. § 1357 or in 02-322 C.M.R. ch. 2.

Does an engineering firm need a Maine certificate of authorization?

No. Maine has no certificate of authorization for engineering firms. 32 M.R.S. § 1253 provides only that “A firm, copartnership, corporation or joint stock association may engage in the practice of professional engineering in this State, provided that the practice is carried on only by professional engineers licensed in this State.” There is no firm number for the document and no firm seal.

I hold a Maine temporary license. Which seal do I use?

Your home jurisdiction seal, with the Maine number written underneath. Under § 9(11), a licensee holding a Maine temporary license stamps with the seal of the home jurisdiction and writes the Maine temporary license number beneath it, with signature and date. There is no separate Maine temporary seal to order.

Acorn Sales Advantages

Made in USAMade in USA
6 Month Stamp Warranty6 Month Stamp Warranty
Free Electronic SealsFree Electronic Seals
FAST 1 Day TurnaroundFAST 1 Day Turnaround
State Board GuaranteeState Board Guarantee
Safe and Secure ShoppingSafe and Secure Shopping